I'm trying to change the order sequence of the wires.
I defined my own rules (device, x/y coordinates...).
My only problem is, that I want to handle also cross connections (daisy chains) with my own rules in order sequence.

My question is: is there a signal/flag/... that indicates, what connections are daisy chains and what wires are part of this daisy chains?

With roles it's a easy task to get the information, how many connections are connected to a pin (Rb108;R#1109;), but how are the different wires a linked together?

The EB cross connection macro needs this informations also in my opionion.

Thank you very much for your help.
Adrian Schilling marked this post as Resolved — 11 months ago
2 years ago
·
#2146
0
Votes
Undo
to control the wiring sequence you can use the attribute Wiring Sequence number (Verdrahtungsreihenfolge) at the pins in a net. It must be a simple number. If you do that via program I think you have to rebuilt the automatic wires after that.